Dairy Supplies - IBA Inflation Systems

Vision Inflation System

  • Improved teat end condition on all test farms
  • Helped reduce and maintain low somatic cell counts
  • Clinical cases appear to be decreased on farms where they were closely observed and recorded
  • Reduced Machine-on-Time even with increased milk production
  • Significantly reduced liner slips on all eight farms
  • Cow comfort during milking improved significantly
  • Acceptance of the Vision Inflations appears to be very high with First Calf Heifers

 

ProSquare Inflations can be used in all standard milking machines. This feature and benefits of using the IBA ProSquare Inflations are evident from the thousands of satisfied dairymen who use these inflations. In fact, many of the highest producing and largest sized herds successfully use IBA ProSquare Inflations. The technology behind the square design has been proven effective in maintaining excellent teat and condition and milking efficiency.

 

Scheduled Liner Replacement
The numbers in the center of the table represent recommended number of days usage
based on 2 times per day milking and 1200 individual cow milkings.

Number of Cows in Milking Herd
# of
Milking
Units
 
40
60
80
100
120
140
160
180
200
250
300
350
400
500
600
1000
3
44
30
22
17
 
 
 
 
 
 
 
 
 
 
 
 
4
60
40
30
24
20
 
 
 
 
 
 
 
 
 
 
 
6
85
60
44
35

30

25
22
20
17
 
 
 
 
 
 
 
12
171
120
85
70
60
50
44
40
35
28
24
20
17
 
 
 
16
 
150
120
92
80
66
60
52
48
37
31
27
24
19
 
 
20
 
 
150
120
100
85
75
66
60
48
40
34
30
24
20
 
24
 
 
171
133
120
100
85
80
70
57
48
40
35
28
24
 
32
 
 
 
180
150
133
120
100
92
75
63
54
48
37
31
19
36
 
 
 
 
171
150
133
120
100
85
70
60
52
42
35
21
40
 
 
 
 
 
171
150
133
120
92
80
66
60
48
40
24
60
 
 
 
 
 
 
 
 
171
133
120
100
85
70
60
35

Example: With 16 milking units and 160 milking cows, the replacement interval should be 60 days.
Regardless of the number of individual cow milkings rubber inflations should be used no longer than 6 month.

To calculate inflation life for values other than those listed inthe chart to the left, use the following formula:

# of cows milked     x     # of milkings per day     ÷     # of milking units     =     # of milkings per day per unit